GLC X
GLC X Controller
Part Number: 26A814
GLC X
GLC X Controller
Part Number: 26A814
The powerful, new, easy-to-use Graco GLC X auto lubrication controller captures more information more ways, so operators, technicians and managers can make faster, smarter decisions that drive more productivity.
Questions About this Product?
If you’re not finding the information you need, ask one of our experts.
Ask an ExpertFeatures
Product Brochure
The powerful, new, easy-to-use Graco GLC X auto lubrication controller captures more information more ways, so operators, technicians and managers can make faster, smarter decisions that drive more productivity.
- Indoor/Outdoor Mountable (IP69K) – Designed to withstand all the elements, including high-pressure washes and inclement weather encountered at the harshest and dirtiest sites.
- Easy-to-Read LED Screen – Soft amber LED lighting capable of displaying text codes, faults and other data clearly in any ambient light without distracting operators.
- Real-Time System Reporting – Program and display a wide range of customizable functions – including lubrication intervals, pressure limits, lubricant levels and more.
- Smart Device and Mobile App – With the Auto Lube™ pap, monitor lubrication levels, configure settings, track history and share important diagnostics.
- Universal Compatibility – One controller for all your lubrication systems simplifies training and inventory.
- Active Current Protection – 9-30 VDC, 10 Amp continuous power supply protects grease pumps from over current and entire system from misfires, electrical shorts and surges.
Specifications & Documents
Technical Specifications
Convert to ImperialApplication | In-Plant Machinery, Off-Road Equipment, On-Road Vehicles |
---|---|
Auxiliary Alarm Max Switching Current (A) | 10 |
Auxiliary Alarm Max Switching Voltage (VDC) | 9-30 |
Auxiliary Alarm Voltage | 9-30 VDC |
Count Rate (counts/sec @ 50% duty cycle) | 5 |
Current Consumption (A) | 15 |
Intrusion Rating | IP69K |
Low Level Alarm Max Switching Current (A) | 10 |
Low Level Alarm Max Switching Voltage (VDC) | 30 |
Lubrication Level Input | Input 1: 10V |
Machine Count Control Input | Input 4 |
Maximum Operating Temperature (°F) | 158 |
Maximum Program Time (min) | 99 |
Maximum Program Time (sec) | 5999 |
Maximum Storage Temperature (°F) | 158 |
Maximum System Cycle Count | 100 |
Maximum Voltage (V dc) | 30 |
Maximum Voltage (V) | 30 |
Minimum Ambient Temperature (°F) | -22 |
Minimum Monitor Time (hrs) | 0 |
Minimum Monitor Time (min) | 1 |
Minimum Monitor Time (sec) | 0 |
Minimum Monitor Time (strokes) | 1 |
Minimum Operating Temperature (°F) | -22 |
Minimum Program Time (hrs) | 0 |
Minimum Program Time (min) | 0 |
Minimum Program Time (sec) | 10 |
Minimum Program Time (strokes) | 1 |
Minimum Storage Temperature (°F) | -22 |
Minimum System Cycle Count | 1 |
Minimum Voltage (V DC) | 9 |
Minimum Voltage (V) | 9 |
Model | GLC |
Number of Pieces | 1 |
Overall Depth (in) | 1.98 |
Overall Height (in) | 6.66 |
Overall Width (in) | 3.62 |
Power Consumption (W) | 450 |
Power Source | Electric |
Pump Control Max Switching Current (A) | 10 |
Pump Control Max Switching Voltage (VDC) | 30 |
Pump Control Voltage (VDC) | 9-30 |
Series | X |
Type | Controller |
Weight (lb) | 0.7 |
Application | In-Plant Machinery, Off-Road Equipment, On-Road Vehicles |
Auxiliary Alarm Max Switching Current (A) | 10 |
Auxiliary Alarm Max Switching Voltage (VDC) | 9-30 |
Auxiliary Alarm Voltage | 9-30 VDC |
Count Rate (counts/sec @ 50% duty cycle) | 5 |
Current Consumption (A) | 15 |
Intrusion Rating | IP69K |
Low Level Alarm Max Switching Current (A) | 10 |
Low Level Alarm Max Switching Voltage (VDC) | 30 |
Lubrication Level Input | Input 1: 10V |
Machine Count Control Input | Input 4 |
Maximum Operating Temperature (°C) | 70 |
Maximum Program Time (min) | 99 |
Maximum Program Time (sec) | 5999 |
Maximum Storage Temperature (°C) | 70 |
Maximum System Cycle Count | 100 |
Maximum Voltage (V dc) | 30 |
Maximum Voltage (V) | 30 |
Minimum Monitor Time (hrs) | 0 |
Minimum Monitor Time (min) | 1 |
Minimum Monitor Time (sec) | 0 |
Minimum Monitor Time (strokes) | 1 |
Minimum Operating Temperature (°C) | -30 |
Minimum Program Time (hrs) | 0 |
Minimum Program Time (min) | 0 |
Minimum Program Time (sec) | 10 |
Minimum Program Time (strokes) | 1 |
Minimum Storage Temperature (°C) | -30 |
Minimum System Cycle Count | 1 |
Minimum Voltage (V DC) | 9 |
Minimum Voltage (V) | 9 |
Model | GLC |
Number of Pieces | 1 |
Overall Depth (cm) | 5 |
Overall Height (cm) | 16.9 |
Overall Height (mm) | 169 |
Overall Width (cm) | 9.2 |
Overall Width (mm) | 92 |
Power Consumption (W) | 450 |
Power Source | Electric |
Pump Control Max Switching Current (A) | 10 |
Pump Control Max Switching Voltage (VDC) | 30 |
Pump Control Voltage (VDC) | 9-30 |
Series | X |
Type | Controller |
Weight (kg) | 319 |